Flared Tube Fitting

Requirements

Flared Tube Connectors with Flared Tube Adaptor (DIN 3949)

Preparation of tube:

  • Cut in 90 ° angle. Angle tolerance of 0.5 ° is tolerable!
  • Slide pressure ring and swivel nut on tube as illustrated.

Assembly with flaring machine

Caution: Read documentation of the flaring machine before usage!

  • Flare tube with flaring machine.

  • Check tube for suitable flare: the diameter of the flare must comply with the values specified in the table below.

Bördelverschraubung - Rohrlängenbestimmung

Flared Tube Fitting - Determining Tube Length

d
[mm]
68101215161820
s
[mm]
11,511,5211,5211,521,522,51,522,531,522,522,533,5
x1
[mm]
12122,5123123123011,52,5011,51234
L1
[mm]
89899,58910891089108,59,510117,58,5911,512,513,514,5
Da min
[mm]
9,111,313,115,319,120,623,225,6
Da max
[mm]
1012141620222426,8

Installation in final location

  • Apply threads of the fitting with lubrication
  • Insert flare adapter into tube fitting.
  • Fasten swivel nut with spanner until the intermediate ring is firmly attached in the shaft.
  • Tighten nut approx. 1/4 rotation after sharp increase of required force.

Repeated Installation

  • The swivel nut is tightened without increased force when the installation is repeated.

Bördelverschraubung - Rohrlängenbestimmung

Flared Tube Fitting - Determining Tube Length

d
[mm]
22252830353842
s
[mm]
1,522,5322,53422,5322,534522,5342,5345234
x1
[mm]
1233,511,52,541,52,53-0,50,5134,51,5234,500,5241,534,5
L1
[mm]
8,59,510,5111313,514,51691010,5131414,516,5181212,513,5151616,5182012,51415,5
Da min
[mm]
26,531,132,73741,84648,8
Da max
[mm]
27,53333,338,742,747,249,8
Go back (Installation Guides)